← 案例手册 / incompressible_flow / Inc_Combustion

❌ FAILED

Config: 1__premixed_hydrogen/H2_burner.cfg · Elapsed: 4.2s · Exit: 1

Iterations
0
CL (Lift Coef)
N/A
CD (Drag Coef)
N/A
CL/CD Ratio
N/A
Wall Time
4.2s
Warnings (5)
WARNING: SURFACE_PRESSURE_DROP can only be computed for at least 2 surfaces (outlet, inlet, ...)
Warning: No (valid) fields chosen for time convergence monitoring. Time convergence monitoring inactive.
Warning: There is no restart file (flow.meta).
Error in "CFluidFlamelet::CFluidFlamelet(CConfig*, su2double)":
------------------------------ Error Exit -------------------------------

Simulation Log (last 40 lines)

Checking the numerical grid orientation. All volume elements are correctly oriented. There has been a re-orientation of 913 LINE surface elements. Identifying edges and vertices. Setting the control volume structure. Area of the computational grid: 5.85864e-06. Searching for the closest normal neighbors to the surfaces. Storing a mapping from global to local point index. Compute the surface curvature. Max K: 167962. Mean K: 1535.04. Standard deviation K: 12501. Computing mesh quality statistics for the dual control volumes. +--------------------------------------------------------------+ | Mesh Quality Metric| Minimum| Maximum| +--------------------------------------------------------------+ | Orthogonality Angle (deg.)| 65.5129| 89.7862| | CV Face Area Aspect Ratio| 1.00006| 7.12014| | CV Sub-Volume Ratio| 1| 3.18843| +--------------------------------------------------------------+ Finding max control volume width. Wetted area = 0 m. Area projection in the x-plane = 0 m, y-plane = 0 m. Max. coordinate in the x-direction = -1e+10 m, y-direction = -1e+10 m. Min. coordinate in the x-direction = 1e+10 m, y-direction = 1e+10 m. Computing wall distances. -------------------- Solver Preprocessing ( Zone 0 ) -------------------- Warning: There is no restart file (flow.meta). Computation will continue without updating metadata parameters. Number of scalars: 4 Number of user scalars: 1 Number of control variables: 3 *********************************************** *** initializing the multi-layer perceptron *** *********************************************** Error in "CFluidFlamelet::CFluidFlamelet(CConfig*, su2double)": ------------------------------------------------------------------------- SU2 was not compiled with MLPCpp enabled (-Denable-mlpcpp=true). ------------------------------ Error Exit -------------------------------
← 返回案例手册